Description
FLIR Thermal Camera PT-Series firmware version 8.0.0.64 contains multiple unauthenticated remote command injection vulnerabilities in the controllerFlirSystem.php script. Attackers can execute arbitrary system commands as root by exploiting unsanitized POST parameters in the execFlirSystem() function through shell_exec() calls. Exploitation evidence was observed by the Shadowserver Foundation on 2026-01-06 (UTC).
Problem types
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Product status
8.0.0.64
Credits
LiquidWorm as Gjoko Krstic of Zero Science Lab
References
www.zeroscience.mk/en/vulnerabilities/ZSL-2017-5438.php
www.zeroscience.mk/en/vulnerabilities/ZSL-2017-5438.php (Zero Science Lab Vulnerability Advisory)
www.exploit-db.com/exploits/42785/ (Exploit Database Entry 42785)
packetstormsecurity.com/files/144321 (Packet Storm Security Exploit Archive)
cxsecurity.com/issue/WLB-2017090203 (CXSecurity Vulnerability Listing)
web.archive.org/....flir.com/security/blog/details/?ID=87043 (Archived FLIR Security Advisory)