Home

Description

A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected SIMATIC RTLS Locating Manager Clients do not properly check the integrity of update files. This could allow an unauthenticated remote attacker to alter update files in transit and trick an authorized user into installing malicious code. A successful exploit requires the attacker to be able to modify the communication between server and client on the network.

PUBLISHED Reserved 2024-03-25 | Published 2024-05-14 | Updated 2024-08-02 | Assigner siemens




HIGH: 8.8CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C
HIGH: 8.8CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

Problem types

CWE-494: Download of Code Without Integrity Check

Product status

Default status
unknown

Any version before V3.0.1.1
affected

Default status
unknown

Any version before V3.0.1.1
affected

Default status
unknown

Any version before V3.0.1.1
affected

Default status
unknown

Any version before V3.0.1.1
affected

Default status
unknown

Any version before V3.0.1.1
affected

Default status
unknown

Any version before V3.0.1.1
affected

Default status
unknown

Any version before V3.0.1.1
affected

References

cert-portal.siemens.com/productcert/html/ssa-093430.html

cert-portal.siemens.com/productcert/html/ssa-093430.html

cve.org (CVE-2024-30206)

nvd.nist.gov (CVE-2024-30206)

Download JSON