We use these services and cookies to improve your user experience. You may opt out if you wish, however, this may limit some features on this site.
Please see our statement on Data Privacy.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly implement brute force protection against user credentials in its Client Communication component. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.
Reserved 2024-07-01 | Published 2024-07-09 | Updated 2025-05-01 | Assigner siemensCWE-307: Improper Restriction of Excessive Authentication Attempts
cert-portal.siemens.com/productcert/html/ssa-381581.html