Description

A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not authenticate GET requests that execute specific commands (such as `ping`) on operating system level.

PUBLISHED Reserved 2024-10-04 | Published 2024-10-23 | Updated 2024-10-23 | Assigner siemens




HIGH: 7.2CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:N
MEDIUM: 6.9CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:L/SI:L/SA:N

Problem types

CWE-306: Missing Authentication for Critical Function

Product status

Default status
unknown

Any version before V8.2.12
affected

Default status
unknown

Any version before V7.2.12
affected

References

cert-portal.siemens.com/productcert/html/ssa-333468.html

cve.org (CVE-2024-47902)

nvd.nist.gov (CVE-2024-47902)

Download JSON