Description

The administrative credentials can be extracted through application API responses, mobile application reverse engineering, and device firmware reverse engineering. The exposure may result in an attacker gaining full administrative access to the Gardyn IoT Hub exposing connected devices to malicious control.

PUBLISHED Reserved 2025-02-11 | Published 2026-02-25 | Updated 2026-02-25 | Assigner icscert




CRITICAL: 9.3CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N

CRITICAL: 9.1CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

Problem types

CWE-798 Use of Hard-coded Credentials

Product status

Default status
unaffected

Any version before master.619
affected

Default status
unaffected

Any version before 2.11.0
affected

Default status
unaffected

Any version before 2.12.2026
affected

Credits

Michael Groberman reported this vulnerability to CISA. finder

References

mygardyn.com/security/

www.cisa.gov/news-events/ics-advisories/icsa-26-055-03

github.com/...p/csaf_files/OT/white/2026/icsa-26-055-03.json

cve.org (CVE-2025-1242)

nvd.nist.gov (CVE-2025-1242)