A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process.

PUBLISHED Reserved 2025-01-15 | Published 2025-03-11 | Updated 2025-03-11 | Assigner siemens




HIGH: 7.8CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
HIGH: 7.3CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Problem types

CWE-416: Use After Free

Product status

Default status
unknown

Any version before V14.3.0.13
affected

Default status
unknown

Any version before V2312.0009
affected

Default status
unknown

Any version before V2406.0007
affected

Default status
unknown

Any version before V2412.0002
affected

Default status
unknown

Any version before V2302.0021
affected

Default status
unknown

Any version before V2404.0010
affected

References

cert-portal.siemens.com/productcert/html/ssa-050438.html

cve.org (CVE-2025-23402)

nvd.nist.gov (CVE-2025-23402)