Home

Description

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportDatabase' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25924)

PUBLISHED Reserved 2025-03-14 | Published 2025-04-16 | Updated 2025-04-16 | Assigner siemens




HIGH: 8.8CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
HIGH: 8.7CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Problem types

CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')

Product status

Default status
unknown

Any version before V3.1.2.2
affected

References

cert-portal.siemens.com/productcert/html/ssa-443402.html

cve.org (CVE-2025-30030)

nvd.nist.gov (CVE-2025-30030)

Download JSON