Home

Description

An unauthenticated user with management network access can get and modify the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) configuration. The device has two web servers that expose unauthenticated REST APIs on the management network (TCP ports 8084 and 8086). An attacker can use these APIs to get access to all system settings, modify the configuration and execute some commands (e.g., system reboot).

PUBLISHED Reserved 2025-04-10 | Published 2025-07-09 | Updated 2025-07-09 | Assigner ENISA




CRITICAL: 9.9CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:L

Problem types

CWE-306: Missing Authentication for Critical Function

Product status

Default status
unaffected

1.20 (semver) before 3.02-1
affected

References

www.cvcn.gov.it/cvcn/cve/CVE-2025-3498 government-resource

cve.org (CVE-2025-3498)

nvd.nist.gov (CVE-2025-3498)

Download JSON