Home

Description

Weak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to derive the password from the SSID. In addition, if the product is configured to enable the individual air conditioner control function, an attacker who has access to the Wi-Fi communication between the units by exploiting this vulnerability may be able to execute ECHONET Lite commands to perform operations such as turning the air conditioner on or off and changing the set temperature. The individual air conditioner control function is available only in display unit version 02.00.01 or later and measurement unit version 02.03.01 or later. The affected products discontinued in 2015, support ended in 2020.

PUBLISHED Reserved 2025-05-21 | Published 2025-07-10 | Updated 2025-09-19 | Assigner Mitsubishi




MEDIUM: 6.5CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Problem types

CWE-521 Weak Password Requirements

Product status

Default status
unaffected

All versions
affected

Default status
unaffected

All versions
affected

References

www.mitsubishielectric.com/...nerability/pdf/2025-007_en.pdf vendor-advisory

jvn.jp/vu/JVNVU90283680/ government-resource

cve.org (CVE-2025-5022)

nvd.nist.gov (CVE-2025-5022)

Download JSON