Home

Description

A command injection vulnerability in COMFAST CF-XR11 (firmware V2.7.2) exists in the multi_pppoe API, processed by the sub_423930 function in /usr/bin/webmgnt. The phy_interface parameter is not sanitized, allowing attackers to inject arbitrary commands via a POST request to /cgi-bin/mbox-config?method=SET&section=multi_pppoe. When the action parameter is set to "one_click_redial", the unsanitized phy_interface is used in a system() call, enabling execution of malicious commands. This can lead to unauthorized access to sensitive files, execution of arbitrary code, or full device compromise.

PUBLISHED Reserved 2025-08-17 | Published 2025-09-18 | Updated 2025-09-19 | Assigner mitre

References

github.com/...thub.io/blob/main/comfast/multi_pppoe.markdown

cve.org (CVE-2025-57293)

nvd.nist.gov (CVE-2025-57293)

Download JSON