Home
HIGH: 8.5 CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NDefault status
unaffected
? (semver) before 0.63.0
affected
Description
Lack of authorization of the InputManager D-Bus interface in InputPlumber versions before v0.63.0 can lead to local Denial-of-Service, information leak or even privilege escalation in the context of the currently active user session.
Problem types
CWE-863: Improper Authorization
Product status
? (semver) before 0.63.0
Credits
Matthias Gerstner of SUSE
References
bugzilla.suse.com/show_bug.cgi?id=CVE-2025-66005
security.opensuse.org/...inputplumber-lack-of-dbus-auth.html