Home

Description

Lack of authorization of the InputManager D-Bus interface in InputPlumber versions before v0.63.0 can lead to local Denial-of-Service, information leak or even privilege escalation in the context of the currently active user session.

PUBLISHED Reserved 2025-11-19 | Published 2026-01-14 | Updated 2026-01-14 | Assigner suse




HIGH: 8.5CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Problem types

CWE-863: Improper Authorization

Product status

Default status
unaffected

? (semver) before 0.63.0
affected

Credits

Matthias Gerstner of SUSE finder

References

bugzilla.suse.com/show_bug.cgi?id=CVE-2025-66005

security.opensuse.org/...inputplumber-lack-of-dbus-auth.html

cve.org (CVE-2025-66005)

nvd.nist.gov (CVE-2025-66005)