Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.

PUBLISHED Reserved 2025-11-21 | Published 2026-01-09 | Updated 2026-01-09 | Assigner CERT-PL




CRITICAL: 9.3CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Problem types

CWE-1393 Use of Default Password

Product status

Default status
unknown

0200a (custom)
affected

Credits

Szymon Paszun finder

References

cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory

cve.org (CVE-2025-66050)

nvd.nist.gov (CVE-2025-66050)

Download JSON