Home

Description

Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.

PUBLISHED Reserved 2025-11-21 | Published 2026-01-09 | Updated 2026-01-09 | Assigner CERT-PL




MEDIUM: 6.9CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

Problem types

CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')

Product status

Default status
unknown

0200a (custom)
affected

Credits

Szymon Paszun finder

References

cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory

cve.org (CVE-2025-66051)

nvd.nist.gov (CVE-2025-66051)

Download JSON