Home

Description

Asseco InfoMedica is a comprehensive solution used to manage both administrative and medical tasks in the healthcare sector. Passwords of all users are stored in a database in an encoded format. An attacker in possession of these encoded passwords is able to decode them by using an algorithm embedded in the client-side part of the software. This vulnerability has been fixed in versions 4.50.1 and 5.38.0

PUBLISHED Reserved 2025-07-29 | Published 2026-01-08 | Updated 2026-01-08 | Assigner CERT-PL




MEDIUM: 5.9CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

Problem types

CWE-257 Storing Passwords in a Recoverable Format

Product status

Default status
unaffected

5.0.0 (semver) before 5.38.0
affected

4.0.0 (semver) before 4.50.1
affected

Credits

Maciej Kazulak finder

References

cert.pl/en/posts/2026/01/CVE-2025-8306/ third-party-advisory

cve.org (CVE-2025-8307)

nvd.nist.gov (CVE-2025-8307)

Download JSON