Home

Description

A vulnerability has been identified in SINEC NMS (All versions < V4.0 SP2). The affected application permits improper modification of a configuration file by a low-privileged user. This could allow an attacker to load malicious DLLs, potentially leading to arbitrary code execution with administrative privilege.(ZDI-CAN-28107)

PUBLISHED Reserved 2026-02-04 | Published 2026-02-10 | Updated 2026-02-10 | Assigner siemens




HIGH: 7.8CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
HIGH: 8.5CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Problem types

CWE-427: Uncontrolled Search Path Element

Product status

Default status
unknown

Any version before V4.0 SP2
affected

References

cert-portal.siemens.com/productcert/html/ssa-311973.html

cve.org (CVE-2026-25655)

nvd.nist.gov (CVE-2026-25655)

Download JSON