Home

Description

Missing Authentication for Critical Function vulnerability in Honeywell Handheld Scanners allows Authentication Abuse.This issue affects Handheld Scanners: from C1 Base(Ingenic x1000) before GK000432BAA, from D1 Base(Ingenic x1600) before HE000085BAA, from A1/B1 Base(IMX25) before BK000763BAA_BK000765BAA_CU000101BAA. This vulnerability could allow a remote attacker within Bluetooth range of the scanner's base station has the capability to remotely execute system commands on the host connected to the base station without authentication. This issue has been assigned CVE-2026-4272 https://nvd.nist.gov/vuln/detail/CVE-2026-4272 and rated with a severity of High. Honeywell strongly recommends that users upgrade to the latest version identified to resolve the vulnerability.

PUBLISHED Reserved 2026-03-16 | Published 2026-04-05 | Updated 2026-04-06 | Assigner Honeywell




HIGH: 8.1CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N

Problem types

CWE-306 Missing Authentication for Critical Function

Product status

Default status
unaffected

C1 Base(Ingenic x1000) (custom) before GK000432BAA
affected

D1 Base(Ingenic x1600) (custom) before HE000085BAA
affected

A1/B1 Base(IMX25) (custom) before BK000763BAA_BK000765BAA_CU000101BAA
affected

Credits

Kaspersky finder

Haidar Kabibo finder

References

https//nvd.nist.gov/vuln/detail/CVE-2026-4272

cve.org (CVE-2026-4272)

nvd.nist.gov (CVE-2026-4272)

Download JSON