Home

Description

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The application does not properly sanitize user input in the /api/sftp/uploadFiles endpoint, allowing the injection of shell command payloads via crafted directory names. These payloads are stored and executed when directory listings are retrieved. This could allow an authenticated remote attacker to execute arbitrary commands on the underlying operating system with the privileges of the affected service user (sinecins).

PUBLISHED Reserved 2026-05-18 | Published 2026-06-09 | Updated 2026-06-09 | Assigner siemens




HIGH: 8.8CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
HIGH: 8.7CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Problem types

CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

Product status

Default status
unknown

Any version before V1.0 SP2 Update 6
affected

References

cert-portal.siemens.com/productcert/html/ssa-860189.html

cve.org (CVE-2026-46746)

nvd.nist.gov (CVE-2026-46746)

Download JSON