Home

Description

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The affected application does not properly sanitize path input in the `GET /api/sftp/uploadFiles` endpoint used for directory listing. This allows path traversal through crafted input, enabling access to unintended file system locations.

PUBLISHED Reserved 2026-05-18 | Published 2026-06-09 | Updated 2026-06-09 | Assigner siemens




MEDIUM: 4.3CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
MEDIUM: 5.3CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N

Problem types

CWE-26: Path Traversal: '/dir/../filename'

Product status

Default status
unknown

Any version before V1.0 SP2 Update 6
affected

References

cert-portal.siemens.com/productcert/html/ssa-860189.html

cve.org (CVE-2026-46747)

nvd.nist.gov (CVE-2026-46747)

Download JSON