Home
MEDIUM: 4.3 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:NMEDIUM: 5.3 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:NDefault status
unknown
Any version before V1.0 SP2 Update 6
affected
Description
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The affected application does not properly sanitize path input in the `GET /api/sftp/uploadFiles` endpoint used for directory listing. This allows path traversal through crafted input, enabling access to unintended file system locations.
Problem types
CWE-26: Path Traversal: '/dir/../filename'
Product status
Any version before V1.0 SP2 Update 6
References
cert-portal.siemens.com/productcert/html/ssa-860189.html