Description
A vulnerability has been identified in Opcenter X (All versions < V2604). Affected applications do not properly validate the algorithm specified in the JSON Web Token (JWT) header. This could allow an unauthenticated remote attacker to forge arbitrary JWT, bypass authentication mechanisms and impersonate any user including administrative accounts, potentially gaining full unauthorized access to the application.
Problem types
CWE-347: Improper Verification of Cryptographic Signature
Product status
Any version before V2604
References
cert-portal.siemens.com/productcert/html/ssa-096828.html